How many heat resistance tests are there for ultra-high power graphite electrodes?
1. High temperature resistance test: Ultra-high power graphite electrodes need to maintain stable electrical conductivity and heat transfer performance in high temperature environment, so high temperature resistance test is required. Equipment such as high temperature constant temperature box can be used for testing.
Current Carrying Capacity
| Nomina diameter | RP | HP | UHP | ||||
| Current Carrying Capacity | Current Density | Current Carrying Capacity | Current Density | Current Carrying Capacity | Current Density | ||
| in | mm | A | A/cm2 | A | A/cm2 | A | A/cm2 |
| 12 | 300 | 10000-13000 | 14-18 | 13000-17400 | 17-24 | 15000-22000 | 20-30 |
| 14 | 350 | 13500-18000 | 14-18 | 17400-24000 | 17-24 | 20000-30000 | 20-30 |
| 16 | 400 | 18000-23500 | 14-18 | 21000-31000 | 16-24 | 25000-40000 | 19-30 |
| 18 | 450 | 22000-27000 | 13-17 | 25000-40000 | 15-24 | 32000-45000 | 19-27 |
| 20 | 500 | 25000-32000 | 13-16 | 30000-48000 | 15-24 | 38000-55000 | 18-27 |
| 22 | 550 | 32000-40000 | 13-16 | 35000-55000 | 14-22 | 42000-64000 | 17-26 |
| 24 | 600 | 35000-41000 | 13-15 | 41000-61000 | 14-21 | 50000-73000 | 17-25 |
| 28 | 700 | 39000-48000 | 10-12 | 55000-82000 | 14-21 | 67000-99000 | 17-25 |
| 32 | 800 | 43000-54000 | 8-10 | / | / | / | / |
2. Thermal shock performance test: Graphite electrodes are prone to cracking and rupture under high temperature and rapid cooling, so thermal shock performance test is required. Equipment such as thermal shock tester can be used for testing.
How many power tests are there for ultra-high power graphite electrodes?
1. Arc furnace test: The graphite electrode can be heated in an arc furnace to observe its stability and electrical conductivity under high temperature and high pressure conditions, and then verify its power performance.
2. Electrolyzer test: The graphite electrode can be placed in the electrolyzer to observe its effect during the electrolysis process and verify its power performance.
In general, verifying the performance and power of ultra-high power graphite electrodes requires comprehensive consideration of its physical properties, heat resistance and power performance, and comprehensively evaluating its performance through physical performance testing, heat resistance testing and power testing. Only through rigorous verification testing can we ensure that ultra-high power graphite electrodes can work stably and reliably in actual production, and improve production efficiency and product quality.